{"id":2620,"date":"2020-01-24T05:51:20","date_gmt":"2020-01-24T05:51:20","guid":{"rendered":"https:\/\/bvcoend.ac.in\/?page_id=2620"},"modified":"2025-03-12T05:49:51","modified_gmt":"2025-03-12T05:49:51","slug":"electrical-machine-lab","status":"publish","type":"page","link":"https:\/\/bvcoend.ac.in\/index.php\/electrical-machine-lab\/","title":{"rendered":"ELECTRICAL MACHINES LAB"},"content":{"rendered":"[vc_row][vc_column width=&#8221;1\/4&#8243;][vc_wp_custommenu title=&#8221;Imp Links&#8221; nav_menu=&#8221;68&#8243;][\/vc_column][vc_column width=&#8221;3\/4&#8243;][vc_column_text]<span style=\"color: #000000;\"><strong>Lab Room No- <\/strong>B-004<\/span><\/p>\n<p><span style=\"color: #000000;\"><strong>Lab In charge- <\/strong>Dr. Bharat Singh<\/span><\/p>\n<p><span style=\"color: #000000;\"><strong>Lab Attendant \u2013\u00a0<\/strong>Mr. Anuj<\/span><\/p>\n<p><span style=\"color: #000000;\"><strong>Subjects-\u00a0\u00a0\u00a0<\/strong>Electrical Machines\u2212I Lab (EEC\u2010257) &amp; Electrical Machines\u2212II Lab (EEC\u2010256)<\/span><\/p>\n<p><span style=\"color: #000000;\"><b><img loading=\"lazy\" class=\"aligncenter size-large wp-image-8634\" src=\"https:\/\/bvcoend.ac.in\/wp-content\/uploads\/2022\/12\/Screenshot_8-1-1024x300.jpg\" alt=\"\" width=\"1024\" height=\"300\" srcset=\"https:\/\/bvcoend.ac.in\/wp-content\/uploads\/2022\/12\/Screenshot_8-1-1024x300.jpg 1024w, https:\/\/bvcoend.ac.in\/wp-content\/uploads\/2022\/12\/Screenshot_8-1-300x88.jpg 300w, https:\/\/bvcoend.ac.in\/wp-content\/uploads\/2022\/12\/Screenshot_8-1-768x225.jpg 768w, https:\/\/bvcoend.ac.in\/wp-content\/uploads\/2022\/12\/Screenshot_8-1.jpg 1269w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/>About Lab<\/b><strong>:<\/strong><\/span><\/p>\n<p align=\"justify\"><span style=\"color: #000000;\">Electrical Machines Laboratory is intended for students of Electrical &amp; Electronics Engineering, Instrumentation &amp;Control Engineering branches, for conducting various experiments in electrical machines. Electrical machines laboratory is equipped with over 20 experimental setups with several machines which includes DC Machines, Transformers, Alternators, Induction Machines, and Synchronous Motor etc. The lab facilities are enough to perform experiments as per the syllabus and beyond the syllabus. The lab gives the students sufficient practical data and industrial applications of electrical machines. The machine lab is equipped with all kinds of AC and DC machines and transformers required for undergraduate lab session and research activities in the field. Electrical Machines\u2212I (Paper Code: ETEE-253<strong>)\u00a0<\/strong>Electrical Machines\u2212II Lab (Paper Code: ETEE-252) are being conducted in this lab.<\/span><\/p>\n<p align=\"justify\"><span style=\"color: #000000;\"><strong>Hardware Details<\/strong>: DC shunt Generator (1.5kW) coupled with DC motor, DC Shunt Motor (5HP), DC series generator, DC compound generator, 8 single-Phase Transformer (1KVA), 3-Point starter,3-phase squirrel cage induction motor(2HP), 3-phase slip ring induction motor(2HP\/3HP), 1-phase Induction Motor(1HP), Synchronous Motor (5HP), Alternator, Direct online starter, Synchronising panel for parallel operation of Alternator (3KVA), 2 Computer (I5 processor, 2.7Ghz, 8 GB RAM)<\/span><\/p>\n<p align=\"justify\"><span style=\"color: #000000;\"><strong>Software Detail<\/strong>: MATLAB<\/span><\/p>\n<p align=\"justify\"><span style=\"color: #000000;\"><strong>List of Experiment for EM-I LAB (EEC-257) as per new scheme<\/strong><\/span><\/p>\n<ol>\n<li><span style=\"color: #000000;\">To study the construction and operation of various types of starters available in the laboratory for starting DC motors.<\/span><\/li>\n<li><span style=\"color: #000000;\">To study the magnetization characteristics of a separately excited D.C generator at different speeds and to find the critical field resistance at those speeds<\/span><\/li>\n<li><span style=\"color: #000000;\">To control the speed of a DC shunt motor by using: &#8211;<\/span><br \/>\n<span style=\"color: #000000;\">(a) Field control.<\/span><br \/>\n<span style=\"color: #000000;\">(b) Armature \/Rheostatic control.<\/span><br \/>\n<span style=\"color: #000000;\">(c) Supply voltage control.<\/span><\/li>\n<li><span style=\"color: #000000;\">To conduct load test on DC shunt generator and obtain its internal and external characteristics.<\/span><\/li>\n<li><span style=\"color: #000000;\">To perform O.C.\/S.C. tests on a single phase transformer and determine equivalent circuit parameters.<\/span><\/li>\n<li><span style=\"color: #000000;\">To perform load test on a single-phase transformer and determine the following:-<\/span><br \/>\n<span style=\"color: #000000;\">(a) Voltage ratio of transformer.<\/span><br \/>\n<span style=\"color: #000000;\">(b) Efficiency at different loads.<\/span><br \/>\n<span style=\"color: #000000;\">(c) Voltage regulation of the transformer.<\/span><\/li>\n<li><span style=\"color: #000000;\">To perform Polarity test on two single-phase transformers, connect them in parallel and study the load sharing between them.<\/span><\/li>\n<li><span style=\"color: #000000;\">To perform Polarity test on two single-phase transformers, connect them in parallel and study the load sharing between them.<\/span><\/li>\n<li><span style=\"color: #000000;\">To study cut section of a 1- \u03d5 transformer.<\/span><\/li>\n<li><span style=\"color: #000000;\">To study cut section of a DC Machine.<\/span><\/li>\n<\/ol>\n<p align=\"justify\"><span style=\"color: #000000;\"><strong>List of Experiments for EM-II LAB (ETEE-252):<\/strong><\/span><\/p>\n<ol>\n<li><span style=\"color: #000000;\">To perform NO LOAD and BLOCK ROTOR test on 3 phase slip-ring induction motor<\/span><\/li>\n<li><span style=\"color: #000000;\">To draw speed torque characteristics of 3-phase induction motor.<\/span><\/li>\n<li><span style=\"color: #000000;\">To study the effect of rotor resistance variation on 3-phase slip ring induction motor<\/span><\/li>\n<li><span style=\"color: #000000;\">To draw V-curve of synchronous motor at no load half load and full load condition.<\/span><\/li>\n<li><span style=\"color: #000000;\">To conduct no-load and block rotor test on single phase induction motor.<\/span><\/li>\n<li><span style=\"color: #000000;\">To study the effect of capacitor on the starting and running of single-phase induction motor.<\/span><\/li>\n<li><span style=\"color: #000000;\">To find out voltage regulation of AC generator on unity power factor load.<\/span><\/li>\n<li><span style=\"color: #000000;\">perform open circuit and short circuit test on AC generator.<\/span><\/li>\n<li><span style=\"color: #000000;\">To perform parallel operation on three phase alternators.<\/span><\/li>\n<li><span style=\"color: #000000;\">To perform Load test on Three phase Synchronous Generator using VIRTUAL LAB.<\/span><\/li>\n<\/ol>\n[\/vc_column_text][\/vc_column][\/vc_row]\n","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column width=&#8221;1\/4&#8243;][vc_wp_custommenu title=&#8221;Imp Links&#8221; nav_menu=&#8221;68&#8243;][\/vc_column][vc_column width=&#8221;3\/4&#8243;][vc_column_text]Lab Room No- B-004 Lab In charge- Dr. Bharat Singh Lab Attendant \u2013\u00a0Mr. Anuj Subjects-\u00a0\u00a0\u00a0Electrical Machines\u2212I Lab (EEC\u2010257) &amp; Electrical Machines\u2212II Lab (EEC\u2010256) About Lab: Electrical Machines Laboratory is intended for students of Electrical &amp; Electronics Engineering, Instrumentation &amp;Control Engineering branches, for conducting various experiments in electrical machines. Electrical machines&hellip;<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/bvcoend.ac.in\/index.php\/wp-json\/wp\/v2\/pages\/2620"}],"collection":[{"href":"https:\/\/bvcoend.ac.in\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/bvcoend.ac.in\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/bvcoend.ac.in\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/bvcoend.ac.in\/index.php\/wp-json\/wp\/v2\/comments?post=2620"}],"version-history":[{"count":11,"href":"https:\/\/bvcoend.ac.in\/index.php\/wp-json\/wp\/v2\/pages\/2620\/revisions"}],"predecessor-version":[{"id":13103,"href":"https:\/\/bvcoend.ac.in\/index.php\/wp-json\/wp\/v2\/pages\/2620\/revisions\/13103"}],"wp:attachment":[{"href":"https:\/\/bvcoend.ac.in\/index.php\/wp-json\/wp\/v2\/media?parent=2620"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}